BS C TV 24
Product Description:
Designed according to GB 18802.21-2004 / IEC 61643-21:2000. Applied in 75W satellite and TV cable system. DIN rail optional.
Main character:
※ Good discharge capacity, low voltage protection level
※ Multiple protection, quick response, no interruption
※ F socket connection, easy for installation
※ Core components are from international well known supplier
Parameters:
Type
|
BS C TV 24
|
||
Order No.
|
630 030(A)/630 031(B)
|
||
Rated voltage
(max. continuous voltage)
|
Uc
|
24V-
|
|
Nominal current
|
IL
|
2A
|
|
Nominal discharge current (8/20)
|
In
|
≤300V(Iine-shield)
|
|
Voltage protection level at In
|
Up
|
≤60V(Iine-shield)
|
|
Voltage protection level at 1Kv/µs
|
Up
|
5-3000MHz
|
|
Transmission range
|
f
|
1.2dB(5-862MHz); 1.4dB(862-2400MHz); 2dB(2400-3000MHz);
|
|
Insertion loss
|
aE
|
≥14dB(5-47MHz); ≥18dB(47-3000MHz);
|
|
Return loss (input /output)
|
aR
|
≥85dB(5-300MHz); ≥80dB(300-470MHz);
|
|
Shield attenuation
|
aS
|
≥75dB(470-1000MHz); ≥55dB(1000-3000MHz);
|
|
Impedance
|
Z
|
75Ω
|
|
Response time
|
tA
|
≤1ns
|
|
Operating temperature range
|
-40℃…+80℃
|
||
Connection (input/output)
|
F socket
|
||
Shield earthing
|
Indirectly via integrated spark gap and an 1.5mm2 ×300mm outdoor line
|
||
Test standards
|
YD/T 1542-2006;GB 18802.21-2004;IEC 61643-21:2000
|
||
Certification
|
CE (LVD,EMC)
|
||
BS C TV 24 Accessory: Earthing Busbar
|
|||
Type
|
E-5
|
E-10
|
|
Order No.
|
630 002
|
630 003
|